Wsw16 (Function Setting 1) - Ricoh HL-F1 Field Service Manual

Machine code: h558
Table of Contents

Advertisement

1
Redial interval
2
3 to 6
No. of redialings
7
Not used.
8
CRP option
• Selectors 1 through 6: Redial interval and No. of redialings
The machine redials by the number of times set by selectors 3 through 6 at intervals set by selectors
1 and 2.
• Selector 8: CRP option
If a command error occurs in the machine (calling station), the machine usually waits for three seconds
and then makes a retry three times. This CRP option is a request command that can be sent from the
called station for requesting the calling station to retry the failed command immediately.

WSW16 (Function setting 1)

Selector No.
1
Not used.
2
ITU-T (CCITT) superfine recommendation
3 to 6
Not used.
7
Max. document length limitation
8
"Stop/Exit" key pressed during reception
Function
Firmware Switches (WSW)
No. 1 2
0 0 : 5 minutes
0 1 : 1 minute
1 0 : 2 minutes
1 1 : 3 minutes
No. 3 4 5 6
0 0 0 0 : 16 times
0 0 0 1 : 1 times
0 0 1 0 : 2 times
0 0 1 1 : 3 times
1 1 1 1 : 15 times
-
0: Disable 1: Enable
Setting and Specifications
-
0: OFF 1: ON
-
0: 400 cm 1: 90 cm
0: Not functional 1: Functional