Number of DTMF tone signals for inhibiting
6
the detection of CNG during external TAD
7
operation
8
Not used.
• Selectors 6 and 7: Number of DTMF tone signals for inhibiting the detection of CNG during external
TAD operation
If the machine receives this specified number of DTMF tone signals during external TAD operation, it
will not detect CNG afterwards.
If these selectors are set to "1, 1," the CNG detection will not be inhibited.

WSW35 (Function setting 13)

Not used.

WSW36 (Function setting 14)

Selector No.
1
Not used.
2
Not used.
3
4
Not used.
5
Escape from phase C
Function
Firmware Switches (WSW)
No. 6 7
0 0 : 3
0 1 : 2
1 0 : 1
1 1 : OFF
-
Setting and Specifications
-
-
-
0: Yes 1: No
5