Cisco TelePresence SX80
Introduction

Peripherals settings

Peripherals Pairing CiscoTouchPanels EmcResilience

If the Touch controller is used in environments with considerable amounts of
electromagnetic noise present, you may experience an appearance of false signals—for
example as if someone tapped the Touch controller when obviously nobody did so. To cope
with this you may enable the EMC Resilience Mode.
Requires user role: ADMIN
Default value: Off
Value space: Off/On
Off: The EMC resilience is disabled.
On: The EMC resilience is enabled.

Peripherals Pairing CiscoTouchPanels RemotePairing

In order to use Cisco Touch 10 (touch panel) as user interface for the video system, Touch
10 must be either directly connected to the video system or paired to the video system via
LAN. The latter is referred to as remote pairing.
Remote pairing is allowed by default; you must switch this setting Off if you want to prevent
remote pairing.
Requires user role: ADMIN
Default value: On
Value space: Off/On
Off: Remote pairing of Touch 10 is not allowed.
On: Remote pairing of Touch 10 is allowed.
D15328.07 SX80 Administrator Guide CE9.1, JUNE 2017.
Configuration
Peripherals
Maintenance

Peripherals Pairing Ultrasound Volume Mode

This setting applies to the Intelligent Proximity feature. Keep the setting at its default value.
Requires user role: ADMIN, INTEGRATOR
Default value: Dynamic
Value space: Dynamic/Static
Dynamic: The video system adjusts the ultrasound volume dynamically. The volume may
vary up to the maximum level as defined in the Peripherals Pairing Ultrasound Volume
MaxLevel setting.
Static: Use only if advised by Cisco.

Peripherals Pairing Ultrasound Volume MaxLevel

This setting applies to the Intelligent Proximity feature. Set the maximum volume of the
ultrasound pairing message. Refer to the Peripherals Pairing Ultrasound Volume Mode
setting.
Requires user role: ADMIN, INTEGRATOR
Default value: 70
Value space: Integer (0..90)
Select a value in the specified range. If set to 0, the ultrasound is switched off.