Peripherals Pairing CiscoTouchPanels EmcResilience

If the Touch controller is used in environments with considerable amounts of
electromagnetic noise present, you may experience an appearance of false signals—for
example as if someone tapped the Touch controller when obviously nobody did so. To cope
with this you may enable the EMC Resilience Mode.
Requires user role: ADMIN
Default value: Off
Value space: Off/On
Off: The EMC resilience is disabled.
On: The EMC resilience is enabled.

Peripherals Pairing CiscoTouchPanels RemotePairing

In order to use Cisco Touch 10 (touch controller) as user interface for the video system,
Touch 10 must be paired to the video system via the network (LAN). This is referred to as
remote pairing.
Remote pairing is allowed by default; you must switch this setting Off if you want to prevent
remote pairing.
Requires user role: ADMIN
Default value: On
Value space: Off/On
Off: Remote pairing of Touch 10 is not allowed.
On: Remote pairing of Touch 10 is allowed.
D15329.08 SX20 Administrator Guide CE9.2, NOVEMBER 2017.
Configuration
Peripherals
Maintenance

Peripherals Profile Cameras

Define the number of cameras that are expected to be connected to the video system.
This information is used by the video system's diagnostics service. If the number of
connected cameras does not match this setting, the diagnostics service will report it as an
inconsistency.
Requires user role: ADMIN, INTEGRATOR
Default value: Minimum1
Value space: NotSet/Minimum1/0/1/2/3/4/5/6/7
NotSet: No camera check is performed.
Minimum1: At least one camera should be connected to the video system.
0-7: Select the number of cameras that are expected to be connected to the video
system.

Peripherals Profile ControlSystems

Define if a third-party control system, for example Crestron or AMX, is expected to be
connected to the video system. This information is used by the video system's diagnostics
service. If the number of connected control systems does not match this setting, the
diagnostics service will report it as an inconsistency. Note that only one third-party control
system is supported.
If set to 1, the control system must send heart beats to the video system using xCommand
Peripherals Pair and HeartBeat commands. Failing to do so will cause the in-room control
extensions to show a warning that the video system has lost connectivity to the control
system.
Requires user role: ADMIN, INTEGRATOR
Default value: NotSet
Value space: 1/NotSet
1: One third-party control system should be connected to the video system.
NotSet: No check for a third-party control system is performed.