Lenovo NeXtScale nx360 M4 Installation And Service Manual page 322

System x ibm nextscale nx360 m4
Table of Contents

Advertisement

Alert Category
Warning - Other
SNMP Trap ID
60
CIM Information
Prefix: PLAT ID: 0398
User Response
1. Turn off the server and disconnect the power cords. Reconnect the power cords and restart
the server.
2. If the problem remains, (trained technician only) replace the system board.
• 806f0107-0301ffff : An Over-Temperature Condition has been detected on [ProcessorElementName].
(CPU 1)
This message is for the use case when an implementation has detected an Over-Temperature Condition
Detected for Processor.
May also be shown as 806f01070301ffff or 0x806f01070301ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0036
User Response
1. Make sure that the fans are operating. There are no obstructions to the airflow (front and rear of
the server), the air baffles are in place and correctly installed, and the server cover is installed
and completely closed.
2. Make sure that the heat sink for microprocessor n is installed correctly.
3. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
• 806f0107-0302ffff : An Over-Temperature Condition has been detected on [ProcessorElementName].
(CPU 2)
This message is for the use case when an implementation has detected an Over-Temperature Condition
Detected for Processor.
308
IBM NeXtScale nx360 M4 Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents