Lenovo NeXtScale nx360 M4 Installation And Service Manual page 300

System x ibm nextscale nx360 m4
Table of Contents

Advertisement

Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0522
User Response
1. Check for a server firmware update.
2. Make sure that the installed microprocessors are compatible.
3. Make sure the microprocessor 2 expansion board is installed correctly (see Installing the
microprocessor 2 expansion board).
4. (Trained technician only) Replace microprocessor 2.
5. (Trained technician only) Replace microprocessor 2 expansion board.
• 80070228-2e01ffff : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (IPMB IO Error)
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702282e01ffff or 0x800702282e01ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0522
User Response
If the specified sensor is IPMB IO Error, Me Error or ME Flash Error, complete the following steps
until the problem is solved:
1. Restart IMM. If the error still appears, proceed step 2.
2. Update the firmware (UEFI and IMM) to the latest level. If the error still appears, proceed step 3.
3. Replace the node.
80070301-0301ffff : Sensor [SensorElementName] has transitioned to non-recoverable from a
less severe state. (CPU 1 OverTemp)
286
IBM NeXtScale nx360 M4 Installation and Service Guide