Lenovo NeXtScale nx360 M4 Installation And Service Manual page 687

System x ibm nextscale nx360 m4
Table of Contents

Advertisement

User Response
Complete the following steps:
1. Execute the standard DSA memory diagnostics to validate all memory.
2. Make sure that the DSA Diagnostic code is at the latest level.
3. Turn off the system and disconnect it from power.
4. Reseat the memory cards and DIMMs.
5. Reconnect the system to power and turn the system on.
6. Run the test again.
7. Execute the standard DSA memory diagnostics to validate all memory.
8. If the failure remains, refer to "Troubleshooting by symptom" in the system "Installation and
Service Guide" for the next corrective action.
Related links
IBM Support website
Latest level of DSA
Latest level of BMC/IMM
202-902-000 : MemStr Test Failed
Memory size is insufficient to run the test.
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Ensure that all memory is enabled by checking the "Available System Memory" in the "Resource
Utilization" section of the DSA Diagnostic Event log.
2. If necessary, access the Configuration/Setup Utility program by pressing F1 during system
boot and enable all memory.
3. Make sure that the DSA Diagnostic code is at the latest level.
4. Run the test again.
5. Execute the standard DSA memory diagnostics to validate all memory.
6. If the failure remains, refer to "Troubleshooting by symptom" in the system "Installation and
Service Guide" for the next corrective action.
Related links
IBM Support website
Latest level of DSA
Latest level of BMC/IMM
Appendix C. DSA diagnostic test results