2. System Settings
3. Device and I/O ports
4. PCI 64 bit Resource and choose enable
• 80070114-2201ffff : Sensor [SensorElementName] has transitioned from normal to non-critical
state. (TPM Phy Pres Set)
This message is for the use case when an implementation has detected a Sensor transitioned to
non-critical from normal.
May also be shown as 800701142201ffff or 0x800701142201ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Other
SNMP Trap ID
60
CIM Information
Prefix: PLAT ID: 0520
User Response
1. Complete the administrative tasks that require the TPM physical presence switch to be in
the ON position.
2. Restore the physical presence switch to the OFF position.
3. Reboot the system.
4. (Trained technician only) If the error continues, replace the planar.
• 80070128-2e01ffff : Sensor [SensorElementName] has transitioned from normal to non-critical
state. (ME Recovery)
This message is for the use case when an implementation has detected a Sensor transitioned to
non-critical from normal.
May also be shown as 800701282e01ffff or 0x800701282e01ffff
Severity
Warning
Serviceable
Yes
Appendix A. Integrated Management Module II (IMM2) error messages