Lenovo NeXtScale nx360 M4 Installation And Service Manual page 66

System x ibm nextscale nx360 m4
Table of Contents

Advertisement

AC power
DC power
LED (green)
LED (green)
Figure 13. AC power-supply LEDs
The following table describes the problems that are indicated by various combinations of the power-supply
LEDs on an ac power supply and suggested actions to correct the detected problems.
AC power-supply LEDs
AC
DC
Error (!)
On
On
Off
Off
Off
Off
Off
On
Off
On
52
IBM NeXtScale nx360 M4 Installation and Service Guide
Power-supply
error LED (yellow)
Description
Off
Normal operation.
Off
No ac power to the
server or a problem
with the ac power
source.
On
The power supply
has failed.
The power supply
Off
has failed.
On
The power supply
has failed.
Action
1. Check the ac power to the
server.
2. Make sure that the power
cord is connected to a
functioning power source.
3. Restart the server. If the
error remains, check the
power-supply LEDs.
4. If the problem remains,
replace the power-supply.
Replace the power supply.
Replace the power supply.
Replace the power supply.
Notes
This is a normal
condition when no ac
power is present.

Advertisement

Table of Contents
loading

Table of Contents