1. Make sure there is a node filler correctly installed for the empty node slot.
2. Make sure the air baffles are placed and correctly installed; and make sure the node cover
is installed and completely closed.
3. Make sure the fans are operating, and there are no obstructions to the airflow (both front and
rear of the server).
4. Reduce the Ambient temperature. The system must be operating within the specifications. (see
Features and specifications for more information)
• 80010701-1002ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical)
has asserted. (PCI Riser 2 Temp)
This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107011002ffff or 0x800107011002ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0490
User Response
1. Make sure there is a node filler correctly installed for the empty node slot.
2. Make sure the air baffles are placed and correctly installed; and make sure the node cover
is installed and completely closed.
3. Make sure the fans are operating, and there are no obstructions to the airflow (both front and
rear of the server).
4. Reduce the Ambient temperature. The system must be operating within the specifications. (see
Features and specifications for more information)
• 80010701-1501ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical)
has asserted. (PIB Ambient Temp)
This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
Appendix A. Integrated Management Module II (IMM2) error messages
253