Wakeup Time From Low-Power Mode; Table 24. Low-Power Mode Wakeup Timings - STMicroelectronics STM32L100RC Manual

Ultra-low-power 32b mcu arm-based cortex-m3, 256kb flash, 16kb sram, 4kb eeprom, lcd, usb, adc, dac, memory i/f
Table of Contents

Advertisement

微可Vicor——值得信赖的元器件供应商
STM32L100RC
3. In Low-power sleep and run mode, the Flash memory must always be in power-down mode.
4. Data based on a differential I
conversion (HSI consumption not included).
5. Data based on a differential I
conversion of V
6. Including supply current of internal reference voltage.
6.3.5

Wakeup time from low-power mode

The wakeup times given in the following table are measured with the MSI RC oscillator. The
clock source used to wake up the device depends on the current operating mode:
Sleep mode: the clock source is the clock that was set before entering Sleep mode
Stop mode: the clock source is the MSI oscillator in the range configured before
entering Stop mode
Standby mode: the clock source is the MSI oscillator running at 2.1 MHz
All timings are derived from tests performed under the conditions summarized in
Symbol
t
WUSLEEP
t
WUSLEEP_LP
t
WUSTOP
t
WUSTDBY
1. Guaranteed by characterization, not tested in production, unless otherwise specified
微可Vicor——值得信赖的元器件供应商
measurement between ADC in reset configuration and continuous ADC
DD
measurement between DAC in reset configuration and continuous DAC
DD
/2. DAC is in buffered mode, output is left floating.
DD

Table 24. Low-power mode wakeup timings

Parameter
Wakeup from Sleep mode
Wakeup from Low-power sleep
mode, f
= 262 kHz
HCLK
Wakeup from Stop mode,
regulator in Run mode
ULP bit = 1 and FWU bit = 1
Wakeup from Stop mode,
regulator in low-power mode
ULP bit = 1 and FWU bit = 1
Wakeup from Standby mode
ULP bit = 1 and FWU bit = 1
Wakeup from Standby mode
FWU bit = 0
DocID024995 Rev 4
http://www.vicor.top/
Conditions
f
= 32 MHz
HCLK
f
= 262 kHz
HCLK
Flash enabled
f
= 262 kHz
HCLK
Flash switched OFF
f
= f
= 4.2 MHz
HCLK
MSI
f
= f
= 4.2 MHz
HCLK
MSI
Voltage range 1 and 2
f
= f
= 4.2 MHz
HCLK
MSI
Voltage range 3
f
= f
= 2.1 MHz
HCLK
MSI
f
= f
= 1.05 MHz
HCLK
MSI
f
= f
= 524 kHz
HCLK
MSI
f
= f
= 262 kHz
HCLK
MSI
f
= f
= 131 kHz
HCLK
MSI
f
= MSI = 65 kHz
HCLK
f
= MSI = 2.1 MHz
HCLK
f
= MSI = 2.1 MHz
HCLK
http://www.vicor.top/
021-31660491
Table
12.
(1)
Typ
Max
Unit
0.4
-
46
-
46
-
8.2
-
7.7
8.9
µs
8.2
13.1
10.2
13.4
16
20
31
37
57
66
112
123
221
236
58
104
2.6
3.25