resource-allocation: Specifies the resource allocation timeout period, in milliseconds.
vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If you do not specify a VSAN, this
command displays global fabric timer information.
Usage guidelines
If you do not specify the distributed-services, error-detect, or resource-allocation keyword, this
command displays all fabric timers.
Examples
# Display all the fabric timers for VSAN 1.
<Sysname> display fc timer vsan 1
Timer of VSAN 1:
Distributed-services timer: 5000 ms
Error-detect timer:
Resource-allocation timer:

domain auto-reconfigure enable

Use domain auto-reconfigure enable to enable the automatic fabric reconfiguration feature in a VSAN.
Use undo domain auto-reconfigure enable to restore the default.
Syntax
domain auto-reconfigure enable
undo domain auto-reconfigure enable
Default
The automatic fabric reconfiguration feature is disabled in each VSAN.
Views
VSAN view
Predefined user roles
network-admin
Usage guidelines
Only FCF switches and VSANs operating in FCF mode support this command.
This command takes effect only when the fabric configuration feature is enabled.
A fabric reconfiguration triggers a principal switch selection phase.
A disruptive reconfiguration is automatically performed if the domain ID lists overlap when two fabrics
are merged.
A nondisruptive reconfiguration is automatically performed when one of the following conditions exists:
When two fabrics are merged, the principal switch information of the two fabrics is different, and
the domain ID lists are not empty and do not overlap.
A principal link in a fabric goes down.
Examples
# Enable the automatic fabric reconfiguration feature in VSAN 1.
<Sysname> system-view
2000 ms
10000 ms