Parameters
name: Specifies a fabric name, in the format of xx:xx:xx:xx:xx:xx:xx:xx, where x is a hexadecimal
number.
Usage guidelines
Only FCF switches and VSANs operating in FCF mode support this command.
An FCF switch supports assigning a fabric name to each VSAN, in the same format as the WWN (a
64-bit address).
Set the fabric names only when a fabric is built statically. You must set the same fabric name in a VSAN
on all switches in the fabric. In a dynamically built fabric, each VSAN uses the WWN of the principal
switch as the fabric name.
Examples
# Set the fabric name to 10:1 1:12:13:14:15:16:17 in VSAN 1.
<Sysname> system-view
[Sysname] vsan 1
[Sysname-vsan1] fabric-name 10:11:12:13:14:15:16:17

fc domain rcf-reject

Use fc domain rcf-reject to configure a VFC interface to reject the RCF requests received in a VSAN.
Use undo fc domain rcf-reject to restore the default.
Syntax
fc domain rcf-reject vsan vsan-id
undo fc domain rcf-reject vsan vsan-id
Default
A VFC interface does not reject the received RCF requests.
Views
VFC interface view
Predefined user roles
network-admin
Parameters
vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839.
Usage guidelines
Only FCF and FCF-NPV switches support this command.
In a stable fabric, to avoid unnecessary disruptive reconfigurations, you can configure an FC interface to
reject the RCF requests received from a VSAN by replying with a reject message. With this feature, the
switch replies with a reject message and isolates the interface that receives an RCF request.
Examples
# Configure interface VFC 1 to reject the RCF requests received in VSAN 1.
<Sysname> system-view
[Sysname] interface vfc 1
39