Fail-Safe Modules
7.8 1 F-RO DC24V/AC24..230V/5A Digital Electronic Module
Isolation in the series tested with
•
•
•
•
•
Isolation in the type test tested with
•
•
•
•
•
•
Current consumption
•
•
Power dissipation of the module
Status, Interrupts, Diagnostics
Status display
Diagnostic functions
•
Data for Selecting an Actuator*
Output current
•
•
Contact protection (internal)
•
Wire break monitoring
Parallel connection of 2 outputs
Control of a digital input
186
Shield against ET 200S bus connection,
control input, channel 1, channel 2
Control input against ET 200S bus
connection, shield, channel 1, channel 2
ET 200S bus connection against control
voltage, shield, channel 1, channel 2
Channel 1 against shield, ET 200S bus
connection, control voltage, channel 2
Channel 2 against shield, ET 200S bus
connection, control voltage, channel 1
Shield against ET 200S bus connection,
control input, channel 1, channel 2
Control input against ET 200S bus
connection, shield, channel 1, channel 2
ET 200S bus connection against control
voltage, shield, channel 1, channel 2
Channel 1 against shield, ET 200S bus
connection, control voltage, channel 2
Channel 2 against shield, ET 200S bus
connection, control voltage, channel 1
Surge test voltage between control voltage
and channel 1, channel 2
From backplane bus
From control voltage (IN P, IN M)
Diagnostic information can be displayed
Continuous thermal current
Minimum load current
At the relay output
Technical Specifications
600 VDC/1 s
600 VDC/1 s
600 VDC/1 s
2545 VDC/1 s
2545 VDC/1 s
370 VAC / 520 VDC / 1 min
370 VAC / 520 VDC / 1 min
370 VAC / 520 VDC / 1 min
2300 VAC / 3250 VDC / 1 min
2300 VAC / 3250 VDC / 1 min
7200 VDC/5 positive and 5 negative pulses
10 mA, maximum
100 mA, maximum
2.1 W, typical
Green LED
No
Max. 5 A
5 mA
No
No
No
Supported, observe max. total current
Possible
ET 200S Distributed I/O System - Fail-Safe Modules
Installation and Operating Manual, 08/2008, A5E00103686-07