3-7. Printer - Transfer

3-7-1. Transfer Corona Wire

1. Open the upper unit and take out the
master unit.
Caution:
• Do not expose the master unit to light.
• Keep it in a shaded place and cover it with
paper.
• Do not touch the master belt surface.
2. Remove the terminal block [A] (2 screws).
3. Remove bracket [B] (1 screw).
4. Remove tab [C] (1 screw).
5. Remove the transport guide plate (see
section 3-10-5). One of the 5 screws has
a ground wire.
To remove this guide plate, you will need
to push the transfer corona unit towards
the development unit.
6.
Carefully disconnect connector [D] at the
power pack (use long-nosed pliers).