Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Unplug washer or disconnect power.
2. Turn off the water supply to the washer.
3. Remove the control panel (See page 4-4).
4. Remove two 5/16" hex head nuts from the
right end of the UIC.
Ribbon
Connector
5. Gently pull the ribbon connector out of the
connector on the UIC.
6. The extra length of plastic at the end of the
ribbon connector must be bent back over
the top of the end of the ribbon connector,
not down and under, or it will block the
connections preventing operation. (See first
picture in next column)

kEYPAD ASSEMBLY

Two 5/16"
Nuts
4-6
7. Press the end of the bolts down to remove
the keypad assembly from the front side of
the control panel.
NOTE: Keypad assemblies may look
similar across Whirlpool product lines, but
the hardware may be different and not
interchangeable.
8. To remove the buttons from the
subassembly, release the locking tab that
holds each row of push buttons on the back
side of the subassembly. The other end
simply slides out of the slot.
Slot
Tab
9. The electronic membrane pad is glued to
the metal plate of the subassembly and
cannot be separated.
Tab
Slot