Drain Pump Motor - Whirlpool CHW9050 Service Manual

Commercial he front loading washers
Hide thumbs Also See for CHW9050:
Table of Contents

Advertisement

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Unplug washer or disconnect power.
2. Turn off the water supply to the washer.
3. Remove the drain pump (See page 4-22).
4. Remove five #2 Phillips screws securing
the impeller and motor to the filter housing.
The two screws that secure the motor are
slightly longer than the other three.

DRAIN PUMP MOTOR

5. Pull the motor and impeller from the filter
6. Use a flat blade screwdriver to release the
5 Phillips
Screws
7. Slide the impeller off the motor.
4-24
housing.
two tabs securing the impeller to the motor.