Drain Pump - Whirlpool CHW9050 Service Manual

Commercial he front loading washers
Hide thumbs Also See for CHW9050:
Table of Contents

Advertisement

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Unplug washer or disconnect power.
2. Turn off the water supply to the washer.
3. Remove the lower service panel
(See page 4-21).
Pump Motor
Filter
Assembly
Housing
4. Place a towel or shallow pan below the
pump to catch any water that may be left in
the system.

DRAIN PUMP

5. Unscrew the pump filter and pull it out of the
6. To disconnect the tub-to-pump and pump-to-
Pump Impeller
Assembly
4-22
filter housing. If necessary, use a pair of
pliers to loosen it.
drain hose, squeeze the ears of the clamps
and pull the hoses off.
Tub-To-Pump Hose
Drain Pump Filter
Pump-To-Drain Hose