Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Unplug washer or disconnect power.
2. Turn off the water supply to the washer.
3. Remove the control panel (See page 4-4).
4. Remove three T-20 screws at each end of
the bracket and two T-20 screws that attach
the bracket to the chemical dispenser.
Three 1/4" Hex
Head Screws
CONTROL PANEL BRACkET
Two T-20
Screws
5. Disconnect the transformer primary wire
harness connector from near the CCU.
6. Push the free end of wires from the control
panel through the hole in the control panel
bracket and remove the bracket.
Transformer
Wire Harness
Connector
Control Panel
Bracket
4-7
CCU
Free End Of Wires
From Coin Meter