Air Gap Damper - Whirlpool CHW9050 Service Manual

Commercial he front loading washers
Hide thumbs Also See for CHW9050:
Table of Contents

Advertisement

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Unplug washer or disconnect power.
2. Turn off the water supply to the washer.
3. Remove the lower service panel
(See page 4-21)
or
Remove the back panel (See page 4-28).
4. Use a flat blade screwdriver to release one
of the locking tabs and turn the upper half of
the damper body slightly to hold that locking
tab unlocked.
5. Reach around to the other side and release
the other locking tab.
6. Turn the upper half of the damper body 90
degrees and pull the tab out of the slot in
the outer tub.
1/4 Turn
To Unlock
Damper

AIR GAP DAMPER

7. The damper is attached to the base in the
same way, with 2 locking tabs.
To Unlock
Locking Tab
Both Sides
8. To separate the two halves of an air gap
damper, Disconnect either the bottom or the
top of the air gap damper from the washer.
Slide the two halves of the air gap damper
apart to separate them.
NOTE: In the base there is a raised tab that
will keep the damper from rotating in the
wrong direction.
TECH TIP: When removing the outer tub,
the air gap dampers simply separate when
the tub assembly is pulled up out of the
washer.
TECH TIP: When removing the back left air
gap damper, use a hammer and a punch to
level the rear most raised tab, on the base
of the washer.
Locking Tab
Both Sides
Rear Most
Raised Tab
4-34
1/4 Turn
Damper

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Chw9060

Table of Contents