Certification
14.3 Certification Printing
14.3
Certification Printing
Certification printing is allowed if the following conditions are met:
● certification switch is set
● rate is below 2 %
● a communications port has been programmed for a printer
The printout must consist of the following:
● Date: YYYY-MM-DD
● Time: HH:MM:SS
● Instrument ID#: Belt Scale serial number
● Units: Units set in P005
● Start Total: End total of previous print
● End Total: Accumulated totalizer including Start Total
● Net Total: End total minus Start Total
If a power failure occurs during totalization, power failure indicator "PF" will be printed in the
middle of a new line, even if it has been cleared from the screen. "PF" will be cleared from the
screen after printing.
198
BW500 and BW500/L
Operating Instructions, 12/2016, A5E33482052-AD