12.13 Test and Diagnostic (P900 - P951)
12.13.3

P911 mA Output Test

Tests the mA output value for the output selected, outputs 1 to 3 (P911 -01 to -03)
Displays the value from the previous measurement. A test value can be entered and the
displayed value is transmitted to the output. Upon returning to the RUN mode, the parameter
assumes the actual mA output level (
Use the UP and DOWN arrow to scroll the value
BW500/L has one output only
1)
12.13.4

P914 mA Input Value

Displays the current mA input value for the input selected, inputs 1 to 2 (P914 – 01 to -02).
Note
• Not applicable if mA I/O board is not connected.
• Not available for BW500/L
12.13.5

P918 Speed Input Frequency

Displays the frequency of the speed input signal in Hertz.
12.13.6

P931 Running Totalizer

1 = Total 1
2 = Total 2
3 = Verification Total
4 = Material Test Load
5 = Batch Total
6 = NTEP Total
7 = 0Cal Start Total
8 = 0Cal End Total
190
f
= 0).