Communication (P740 - P799)

Note
Changes to these parameters are not effected until the power to the unit is turned off and
then back on.
These parameters cover the various communications formats supported by the BW500 and
BW500/L: serial printer, Dolphin Plus, SmartLinx, and Modbus.
12.11.1

P742 Word Order Parameter

Note
This parameter affects SmartLinx and Modbus communications
This value determines the format of all unsigned, double-register integers (UINT32),
those in the direct parameter access.
Values
f
0
1
12.11.2
P750 – P769 SmartLinx Module Specific Parameters
These parameters are specific to the SmartLinx module installed. Refer to the module
documentation for a list and description of the specific parameter requirements.
12.11.3
P770 – P789 Local Port Parameters
These parameters are specific to programming of the BW500 and BW500/L communication
ports. Refer to Communications (Page 125) for a listing and description of these parameters.
12.12

SmartLinx Hardware Testing

These parameters are used to test and debug a SmartLinx card (if installed).
BW500 and BW500/L
Operating Instructions, 12/2016, A5E33482052-AD
12.11 Communication (P740 - P799)
Description
most significant byte (MSB) is given first
least significant byte (LSB) is given first
Parameters
except for
187

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Milltronics bw500/l

Table of Contents