Advertisement

5.3

Optional Plug-ins

5.3.1

SmartLinx Module

BW500 and BW500/L is software/hardware ready to accept the optional Siemens SmartLinx
communications module that provides an interface to one of several popular industrial
communications systems.
BW500 and BW500/L may be shipped to you without a SmartLinx module, for installation at a
later date.
If you are ready to install your SmartLinx module, or want to change it, please follow the
instructions as outlined.
Installation
1. Isolate power and voltages applied to the BW500 and BW500/L
2. Open the lid
3. Install the module by mating the connectors and secure in place using the two screws
provided
4. Route communication cable to SmartLinx module along the right side of the enclosure wall.
This route will reduce communication
Note
Refer to the SmartLinx documentation for any required hardware settings prior to closing
the lid.
5. Close the lid.
6. Apply power and voltage to the BW500 and BW500/L.
Refer to
● SmartLinx Module in the Specifications (Page 17)
P750 – P769 SmartLinx Module Specific Parameters
(Page 153)
● the SmartLinx manual for wiring
5.3.2

mA I/O board

BW500 is software/hardware ready to accept the optional mA I/O board
provides 2 programmable 0/4 to 20 mA outputs, 2 programmable 0/4 to 20 mA inputs and a
nominal 24 V DC supply for loop powered devices.
Note
Not available with the BW500/L
BW500 and BW500/L
Operating Instructions, 12/2016, A5E33482052-AD
5.3 Optional Plug-ins
in this manual under Parameters
. The mA I/O board
1)
Installation
25