Start Up
6.3 Initial Start Up
The program returns to P015. Calculate the
value per Parameter P690.
P015-01 Speed Constant
Pulses/m
Press the following keys in the
given sequence:
For example: speed constant
of 100.3 pulses per meter
This value is calculated. For manual or automatic calculation, refer to P690 on page 143. To program
Differential Speed (P015-02), follow steps above for P015-01.
P016 Belt Length
Enter Length
m
factory set length
Press the following key:
P016 Belt Length
Enter Length
m
For example belt length of 25 m
Press the following keys:
P017 Test Load: Weight MS 1
Enter test load
kg/m
If P002 Test Load Reference had been set for 2-Chain, the display would read:
or, if 3-ECal refer to ECal parameters (P693 - P699 on page 144)
or, if P002 is set to 1-Weight, pressing enter at P017 invokes P680 for data entry.
Press the following key:
P680 Test Load: Weight MS 1
1-Enter Value, 2-Enter Data
56
Select: 1 - Calculated
For example
belt length of
25 m
P017 Test Load: Chain MS 1
Enter test load
P017 Test Load: ECal MS 1
Enter test load
Select: 2 - Sensor Data
The program advances through parameters P691
and P692 prompting entry from the sensor name-
plate. From this data, the speed constant is calcu-
lated and automatically entered into P015.
E
P691-01 Step 1:
0.0000
Drive Pully Diameter
P692-01 Step 2:
Pulses per sensor Rev.
Enter Pulses
P015-01 Speed Constant
Pulses/m
V
0.00
E
0.000
V
0.00
V
0
Operating Instructions, 12/2016, A5E33482052-AD
V
0.00 mm
V
0.00
V
0.0000
V
0.00 kg/m
V
0.00 kg/m