3.2

Installing the RF170C communication module

Introduction
The RF170C communications module determines the function of the reader outputs. The
connection module is mounted on the communications module.
Requirements
• The interface module is mounted on the rack.
• All communications modules are installed to the right beside the interface module.
• The communications module is plugged into the relevant bus module (delivery state).
Procedure
Follow the steps below to mount the communications module RF170C:
1. Plug the communications module onto the rack until it locks in place.
2. Push the communications module to the left until it engages the interface module or the
previous communications module.
When sliding the RF170C communications module remember that the connection must
not yet be mounted.
Figure 3-2
SIMATIC RF170C
Operating Instructions, 02/2022, J31069-D0176-U001-A6-7618
Mounting the communications module
3.2 Installing the RF170C communication module
Mounting
23