GE L60 Instruction Manual page 154

Ur series line phase comparison relay
Hide thumbs Also See for L60:
Table of Contents

Advertisement

5.4 FLEXLOGIC™
Table 5–7: L60 FLEXLOGIC™ OPERANDS (Sheet 3 of 7)
OPERAND TYPE
OPERAND SYNTAX
ELEMENT:
GROUND IOC1 PKP
Ground
GROUND IOC1 OP
Instantaneous
GROUND IOC1 DPO
Overcurrent
GROUND IOC2
ELEMENT:
GROUND TOC1 PKP
Ground Time
GROUND TOC1 OP
Overcurrent
GROUND TOC1 DPO
GROUND TOC2
ELEMENT
LATCH 1 ON
Non-Volatile
LATCH 1 OFF
Latches
LATCH 16 ON
LATCH 16 OFF
ELEMENT:
LINE PICKUP OP
Line Pickup
LINE PICKUP PKP
LINE PICKUP DPO
LINE PICKUP I<A
LINE PICKUP I<B
LINE PICKUP I<C
LINE PICKUP UV PKP
LINE PICKUP LEO PKP
LINE PICKUP RCL TRIP
ELEMENT:
LOAD ENCHR PKP
Load Encroachment
LOAD ENCHR OP
LOAD ENCHR DPO
ELEMENT:
NEG SEQ DIR OC1 FWD
5
Negative Sequence
NEG SEQ DIR OC1 REV
Directional
NEG SEQ DIR OC2 FWD
Overcurrent
NEG SEQ DIR OC2 REV
ELEMENT:
NEG SEQ IOC1 PKP
Negative Sequence
NEG SEQ IOC1 OP
Instantaneous
NEG SEQ IOC1 DPO
Overcurrent
NEG SEQ IOC2
ELEMENT:
NEG SEQ TOC1 PKP
Negative Sequence
NEG SEQ TOC1 OP
Time Overcurrent
NEG SEQ TOC1 DPO
NEG SEQ TOC2
ELEMENT:
NEUTRAL IOC1 PKP
Neutral
NEUTRAL IOC1 OP
Instantaneous
NEUTRAL IOC1 DPO
Overcurrent
NEUTRAL IOC2
ELEMENT:
NEUTRAL OV1 PKP
Neutral Overvoltage
NEUTRAL OV1 DPO
NEUTRAL OV1 OP
ELEMENT:
NEUTRAL TOC1 PKP
Neutral Time
NEUTRAL TOC1 OP
Overcurrent
NEUTRAL TOC1 DPO
NEUTRAL TOC2
ELEMENT:
NTRL DIR OC1 FWD
Neutral Directional
NTRL DIR OC1 REV
Overcurrent
5-62
OPERAND DESCRIPTION
Ground Instantaneous Overcurrent 1 has picked up
Ground Instantaneous Overcurrent 1 has operated
Ground Instantaneous Overcurrent 1 has dropped out
Same set of operands as shown for GROUND IOC 1
Ground Time Overcurrent 1 has picked up
Ground Time Overcurrent 1 has operated
Ground Time Overcurrent 1 has dropped out
Same set of operands as shown for GROUND TOC1
Non-Volatile Latch 1 is ON (Logic = 1)
Non-Voltage Latch 1 is OFF (Logic = 0)
Non-Volatile Latch 16 is ON (Logic = 1)
Non-Voltage Latch 16 is OFF (Logic = 0)
Line Pickup has operated
Line Pickup has picked up
Line Pickup has dropped out
Line Pickup detected Phase A current below 5% of nominal
Line Pickup detected Phase B current below 5% of nominal
Line Pickup detected Phase C current below 5% of nominal
Line Pickup Undervoltage has picked up
Line Pickup Line End Open has picked up
Line Pickup operated from overreaching Zone 2 when reclosing the line
Load Encroachment has picked up
Load Encroachment has operated
Load Encroachment has dropped out
Negative Sequence Directional OC1 Forward has operated
Negative Sequence Directional OC1 Reverse has operated
Negative Sequence Directional OC2 Forward has operated
Negative Sequence Directional OC2 Reverse has operated
Negative Sequence Instantaneous Overcurrent 1 has picked up
Negative Sequence Instantaneous Overcurrent 1 has operated
Negative Sequence Instantaneous Overcurrent 1 has dropped out
Same set of operands as shown for NEG SEQ IOC1
Negative Sequence Time Overcurrent 1 has picked up
Negative Sequence Time Overcurrent 1 has operated
Negative Sequence Time Overcurrent 1 has dropped out
Same set of operands as shown for NEG SEQ TOC1
Neutral Instantaneous Overcurrent 1 has picked up
Neutral Instantaneous Overcurrent 1 has operated
Neutral Instantaneous Overcurrent 1 has dropped out
Same set of operands as shown for NEUTRAL IOC1
Neutral Overvoltage element has picked up
Neutral Overvoltage element has dropped out
Neutral Overvoltage element has operated
Neutral Time Overcurrent 1 has picked up
Neutral Time Overcurrent 1 has operated
Neutral Time Overcurrent 1 has dropped out
Same set of operands as shown for NEUTRAL TOC1
Neutral Directional OC1 Forward has operated
Neutral Directional OC1 Reverse has operated
L60 Line Phase Comparison Relay
(Zone 1 extension functionality)
5 SETTINGS
GE Multilin