GE L60 Instruction Manual page 399

Ur series line phase comparison relay
Hide thumbs Also See for L60:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 6 of 47)
ADDR
REGISTER NAME
1D04
Source 1 Positive Varhour
1D06
Source 1 Negative Varhour
1D08
Reserved (8 items)
1D10
...Repeated for Source 2
1D20
...Repeated for Source 3
1D30
...Repeated for Source 4
1D40
...Repeated for Source 5
1D50
...Repeated for Source 6
Energy Commands (Read/Write Command)
1D60
Energy Clear Command
Source Frequency (Read Only) (6 modules)
1D80
Frequency for Source 1
1D81
Frequency for Source 2
1D82
Frequency for Source 3
1D83
Frequency for Source 4
1D84
Frequency for Source 5
1D85
Frequency for Source 6
Breaker Flashover (Read/Write Setting) (2 modules)
21A6
Breaker 1 Flashover Function
21A7
Breaker 1 Flashover Side 1 Source
21A8
Breaker 1 Flashover Side 2 Source
21A9
Breaker 1 Flashover Status Closed A
21AA
Breaker 1 Flashover Status Closed B
21AB
Breaker 1 Flashover Status Closed C
21AC
Breaker 1 Flashover Voltage Pickup Level
21AD
Breaker 1 Flashover Voltage Difference Pickup Level
21AF
Breaker 1 Flashover Current Pickup Level
21B0
Breaker 1 Flashover Pickup Delay
21B1
Breaker 1 Flashover Supervision Phase A
21B2
Breaker 1 Flashover Supervision Phase B
21B3
Breaker 1 Flashover Supervision Phase C
21B4
Breaker 1 Flashover Block
21B5
Breaker 1 Flashover Events
21B6
Breaker 1 Flashover Target
21B7
Reserved (4 items)
21BB
...Repeated for Breaker 2 Flashover
Breaker Arcing Current Actuals (Read Only Non-Volatile) (2 modules)
21E0
Breaker 1 Arcing Current Phase A
21E2
Breaker 1 Arcing Current Phase B
21E4
Breaker 1 Arcing Current Phase C
21E6
Breaker 1 Operating Time Phase A
21E7
Breaker 1 Operating Time Phase B
21E8
Breaker 1 Operating Time Phase C
21E9
Breaker 1 Operating Time
21E6
...Repeated for Breaker Arcing Current 2
Breaker Arcing Current Commands (Read/Write Command) (2 modules)
2224
Breaker 1 Arcing Current Clear Command
2225
Breaker 2 Arcing Current Clear Command
Passwords Unauthorized Access (Read/Write Command)
2230
Reset Unauthorized Access
Source Current THD (Read Only) (4 modules)
22A0
Source 1 Ia THD
22A1
Source 1 Ib THD
22A2
Source 1 Ic THD
GE Multilin
RANGE
0 to 1000000000000
0 to 1000000000000
---
0 to 1
2.000 to 90.000
2.000 to 90.000
2.000 to 90.000
2.000 to 90.000
2.000 to 90.000
2.000 to 90.000
0 to 1
0 to 5
0 to 6
0 to 65535
0 to 65535
0 to 65535
0 to 1.5
0 to 100000
0 to 1.5
0 to 65.535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 2
---
0 to 99999999
0 to 99999999
0 to 99999999
0 to 99999999
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 1
0 to 1
0 to 100
0 to 100
0 to 100
L60 Line Phase Comparison Relay
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
varh
0.001
F060
varh
0.001
F060
---
---
F001
---
1
F126
Hz
0.001
F003
Hz
0.001
F003
Hz
0.001
F003
Hz
0.001
F003
Hz
0.001
F003
Hz
0.001
F003
---
1
F102
---
1
F167
---
1
F211
---
1
F300
---
1
F300
---
1
F300
pu
0.001
F001
V
1
F060
pu
0.001
F001
s
0.001
F001
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F102
---
1
F109
---
---
F001
2
kA
-cyc
1
F060
2
kA
-cyc
1
F060
2
kA
-cyc
1
F060
2
kA
-cyc
1
F060
ms
1
F001
ms
1
F001
ms
1
F001
ms
1
F001
---
1
F126
---
1
F126
---
1
F126
%
0.1
F001
%
0.1
F001
%
0.1
F001
DEFAULT
0
0
0
B
0 (No)
0
0
0
0
0
0
0 (Disabled)
0 (SRC 1)
0 (None)
0
0
0
850
1000
600
100
0
0
0
0
0 (Disabled)
0 (Self-Reset)
0
0
0
0
0
0
0
0
0
0 (No)
0 (No)
0 (No)
0
0
0
B-13

Advertisement

Table of Contents
loading

Table of Contents