APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 10 of 47)
ADDR
REGISTER NAME
3519
RTD Input 42 Value
351A
RTD Input 43 Value
351B
RTD Input 44 Value
351C
RTD Input 45 Value
351D
RTD Input 46 Value
351E
RTD Input 47 Value
351F
RTD Input 48 Value
Expanded Direct Input/Output Status (Read Only)
3560
Direct Device States, one per register (8 items)
3570
Direct Input States, one per register (96 items)
Passwords (Read/Write Command)
4000
Command Password Setting
Passwords (Read/Write Setting)
4002
Setting Password Setting
Passwords (Read/Write)
4008
Command Password Entry
400A
Setting Password Entry
Passwords (Read Only)
4010
Command Password Status
4011
Setting Password Status
User Display Invoke (Read/Write Setting)
4040
Invoke and Scroll Through User Display Menu Operand
LED Test (Read/Write Setting)
4048
LED Test Function
4049
LED Test Control
Preferences (Read/Write Setting)
404F
Language
4050
Flash Message Time
4051
Default Message Timeout
4052
Default Message Intensity
4053
Screen Saver Feature
4054
Screen Saver Wait Time
4055
Current Cutoff Level
4056
Voltage Cutoff Level
Communications (Read/Write Setting)
407E
COM1 minimum response time
407F
COM2 minimum response time
4080
Modbus Slave Address
4083
RS485 Com1 Baud Rate
4084
RS485 Com1 Parity
4085
RS485 Com2 Baud Rate
4086
RS485 Com2 Parity
4087
IP Address
4089
IP Subnet Mask
408B
Gateway IP Address
408D
Network Address NSAP
409A
DNP Channel 1 Port
409B
DNP Channel 2 Port
409C
DNP Address
409D
Reserved
409E
DNP Client Addresses (2 items)
40A3
TCP Port Number for the Modbus protocol
40A4
TCP/UDP Port Number for the DNP Protocol
40A5
TCP Port Number for the HTTP (Web Server) Protocol
GE Multilin
RANGE
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
0 to 1
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
0 to 1
0 to 65535
0 to 1
0 to 65535
0 to 3
0.5 to 10
10 to 900
0 to 3
0 to 1
1 to 65535
0.002 to 0.02
0.1 to 1
0 to 1000
0 to 1000
1 to 254
0 to 11
0 to 2
0 to 11
0 to 2
0 to 4294967295
0 to 4294967295
0 to 4294967295
---
0 to 4
0 to 4
0 to 65519
0 to 1
0 to 4294967295
1 to 65535
1 to 65535
1 to 65535
L60 Line Phase Comparison Relay
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
---
1
F155
---
1
F108
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F102
---
1
F102
---
1
F300
---
1
F102
---
1
F300
---
1
F531
s
0.1
F001
s
1
F001
---
1
F101
---
1
F102
min
1
F001
pu
0.001
F001
V
0.1
F001
ms
10
F001
ms
10
F001
---
1
F001
---
1
F112
---
1
F113
---
1
F112
---
1
F113
---
1
F003
---
1
F003
---
1
F003
---
---
F074
---
1
F177
---
1
F177
---
1
F001
---
1
F001
---
1
F003
---
1
F001
---
1
F001
---
1
F001
DEFAULT
0
0
0
0
0
B
0
0
0 (Offline)
0 (Off)
0
0
0
0
0 (Disabled)
0 (Disabled)
0
0 (Disabled)
0
0 (English)
10
300
0 (25%)
0 (Disabled)
30
20
10
0
0
254
8 (115200)
0 (None)
8 (115200)
0 (None)
56554706
4294966272
56554497
0
0 (None)
0 (None)
1
0
0
502
20000
80
B-17

Advertisement

Table of Contents
loading

Table of Contents