Table B–9: MODBUS MEMORY MAP (Sheet 14 of 47)
ADDR
REGISTER NAME
4587
...Repeated for Source 2
458E
...Repeated for Source 3
4595
...Repeated for Source 4
459C
...Repeated for Source 5
45A3
...Repeated for Source 6
Power System (Read/Write Setting)
4600
Nominal Frequency
4601
Phase Rotation
4602
Frequency And Phase Reference
4603
Frequency Tracking Function
Breaker Control (Read/Write Setting) (2 modules)
4700
Breaker 1 Function
4701
Breaker 1 Name
4704
Breaker 1 Mode
4705
Breaker 1 Open
4706
Breaker 1 Close
4707
Breaker 1 Phase A 3 Pole
4708
Breaker 1 Phase B
4709
Breaker 1 Phase C
470A
Breaker 1 External Alarm
470B
Breaker 1 Alarm Delay
470D
Breaker 1 Push Button Control
470E
Breaker 1 Manual Close Recall Time
4710
Breaker 1 Out Of Service
4711
Breaker 1 IEC 61850 XCBR.ST.Loc Status operand
4712
Reserved (6 items)
4718
...Repeated for Breaker 2
Synchrocheck (Read/Write Setting) (2 modules)
4780
Synchrocheck 1 Function
4781
Synchrocheck 1 V1 Source
4782
Synchrocheck 1 V2 Source
4783
Synchrocheck 1 Maximum Voltage Difference
4785
Synchrocheck 1 Maximum Angle Difference
4786
Synchrocheck 1 Maximum Frequency Difference
4787
Synchrocheck 1 Dead Source Select
4788
Synchrocheck 1 Dead V1 Maximum Voltage
4789
Synchrocheck 1 Dead V2 Maximum Voltage
478A
Synchrocheck 1 Live V1 Minimum Voltage
478B
Synchrocheck 1 Live V2 Minimum Voltage
478C
Synchrocheck 1 Target
478D
Synchrocheck 1 Events
478E
Synchrocheck 1 Block
478F
Synchrocheck 1 Frequency Hysteresis
4790
...Repeated for Synchrocheck 2
Flexcurves A and B (Read/Write Settings)
4800
FlexCurve A (120 items)
48F0
FlexCurve B (120 items)
Modbus User Map (Read/Write Setting)
4A00
Modbus Address Settings for User Map (256 items)
User Displays Settings (Read/Write Setting) (16 modules)
4C00
User-Definable Display 1 Top Line Text
4C0A
User-Definable Display 1 Bottom Line Text
4C14
Modbus Addresses of Display 1 Items (5 items)
4C19
Reserved (7 items)
GE Multilin
RANGE
25 to 60
0 to 1
0 to 5
0 to 1
0 to 1
---
0 to 1
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1000000
0 to 1
0 to 1000000
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 5
0 to 5
0 to 400000
0 to 100
0 to 2
0 to 5
0 to 1.25
0 to 1.25
0 to 1.25
0 to 1.25
0 to 2
0 to 1
0 to 65535
0 to 0.1
0 to 65535
0 to 65535
0 to 65535
---
---
0 to 65535
---
L60 Line Phase Comparison Relay
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
Hz
1
F001
---
1
F106
---
1
F167
---
1
F102
---
1
F102
---
---
F206
---
1
F157
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
s
0.001
F003
---
1
F102
s
0.001
F003
---
1
F300
---
1
F300
s
1
F001
---
1
F102
---
1
F167
---
1
F167
V
1
F060
degrees
1
F001
Hz
0.01
F001
---
1
F176
pu
0.01
F001
pu
0.01
F001
pu
0.01
F001
pu
0.01
F001
---
1
F109
---
1
F102
---
1
F300
Hz
0.01
F001
ms
1
F011
ms
1
F011
---
1
F001
---
---
F202
---
---
F202
---
1
F001
---
---
F001
DEFAULT
B
60
0 (ABC)
0 (SRC 1)
1 (Enabled)
0 (Disabled)
"Bkr 1"
0 (3-Pole)
0
0
0
0
0
0
0
0 (Disabled)
0
0
0
0
0 (Disabled)
0 (SRC 1)
1 (SRC 2)
10000
30
100
1 (LV1 and DV2)
30
30
70
70
0 (Self-reset)
0 (Disabled)
0
6
0
0
0
" "
""
0
0
B-21