7. Error Display
JCY-1800/1850 VDR/S-VDR Installation Guide
Table 7-1: ERROR code table of the Operation Panel Unit (2/3)
ALARM DETAIL
SYSYTEM
CODE
3
0
3
1
3
2
3
3
3
4
3
5
3
6
3
7
3
8
4
0
4
1
4
2
5
1
:
9
*
*
6
0
*
*
6
1
DOC No. 7ZPJD0387C
CATEGORY
MCB
MCB Initialize error
An abnormality has been detected in the Main Control Board.
CF CARD alarm
Ten minutes or more has passed since the CF CARD was taken out.
CF CARD media error
The CF CARD does not record data correctly.
Time adjustment error
Time data is not received from GPS, therefore the internal clock of S-VDR
cannot be calibrated.
RTC error
An internal lithium battery for a Real Time Clock IC has run out of the life.
EEPROM check sum error
An abnormal data has been detected in configuration data registered on the
EEPROM of the MCB.
EEPROM access error
The access to the EEPROM IC on the MCB, where setup data are registered.
Flash ROM check sum error
An abnormal data has been detected in configuration data registered on the Flash
ROM of the MCB.
Wrong data registered to MCB
The value registered to the configuration data of the EEPROM on MCB is not
correct.
ARB
ARB Initialize error
An abnormality has been detected in the Audio Recording Board on the
MCB.
ARB control error
The MCB did not fetch the audio data from the ARB successfully.
ARB error
The ARB did not compress/decompress the audio signal successfully.
MIC
MIC test error
An abnormality has been detected during the microphone checkups carried
out at the startup of the equipment and every 12 hours during the operation.
The second digit (1-9) identifies the Microphone Unit out of order.
nd
"2
number (1-9) identify an abnormal Microphone Unit number.
"51__": MIC1 --- "59__": MIC9
Serial data
Serial data (IEC61162-1/2 ) reception error
(NMEA)
The input received from the sensor is not normal.
"**" identifies the sensor that has sent the unreadable data. Refer to table 9.
Serial data (IEC61162-1/2 ) setup error
The setup to receive NMEA serial data is in the wrong.
"**" identifies the equipment. Refer to table 9.