5.1.3.2. How to operate the Data Processor Unit
1. To stop the recording of data onto the Protective Capsule Unit
ATTENTION
1) Press the REC STOP SWITCH on the Main Control Board.
2) The REC LED on the Main Control Board blinks.
3) After about a minute, the blinking REC LED on the Main Control Board and RECORDING LED on the
Operation Panel Unit turn off and the recording of the data into the Protective Capsule Unit stops.
4) When the Recording Control Unit stops recording to the Protective Capsule Unit, the Recording Alarm is
generated. (Error code: 22__)
2. To restart the recording of data into the Protective Capsule Unit
1) Press the REC START SWITCH on the Main Control Board.
2) The REC LED on the Main Control Board lights up.
3) The RECORDING LED on the Operation Panel Unit lights, and the recording of the data into the Protective
capsule Unit starts.
4) When the Recording Control Unit restarts recording to the Protective Capsule Unit, the Recording alarm stops.
3. To back up the data stored in the CF CARD
ATTENTION
Do not remove the CF CARD while the CARD LED on the Main Control Board is on. It could
damage the CF CARD. Make sure that CARD LED is off.
1) Make sure that the CARD LED on the Main Control Board is on.
2) Press the CARD STOP SWITCH on the Main Control Board.
3) The CARD LED on the Main Control Board blinks for about 5 seconds.
4) Make sure that the CARD LED on the Main Control Board turns off. And press the CF CARD EJECT
BUTTON.
5) Take out the CF CARD. Insert the CF CARD with a CARD ADAPTER into the PC that has a PCMCIA slot
and copy the data into the PC.
6) After the copy has been finished, insert the CF CARD into the CARD slot on the Main Control Board. (Be
sure that the CF CARD JRC-label side is pointing right.)
7) Make sure that the CARD LED lights up.
8) Then the recording of data into the CF CARD starts automatically.
9) The old data which had been recorded over 13.5hours previously in the CF CARD is erased.
ATTENTION
Do not halt the recording of data onto the Protective Capsule Unit while the ship is navigating.
Otherwise no data would be recorded, even in case of an accident.
When the CARD LED is left turned off for 10 minutes or more, the MEDIA LED lights up on
the Main Control Board and the Operation Panel Unit gives the alarm with ALARM
BUZZER. ALARM lamp and ERROR CODE LEDs will be blinking. ( Error Code: 31__ ) If
a CF CARD is inserted into the CARD slot in the Main Control Board, the ALARM BUZZER
stops and ALARM LEDs will be off.