4. Cabling
JCY-1800/1850 VDR/S-VDR Installation Guide
4.2.7. Recording Control Unit NDV-1800/1850 – Sensor NMEA data
The following cables are connected to the Recording Control Unit for recoding NMEA data.
• NDV-1800 has 32 ports for inputting NMEA data.
• NDV-1850 has 16 ports for inputting NMEA data. (not installed TB404, 405)
Connection table for sensors: ch1 ~ ch12
CQD-2040
TB401
[CH-1 to 12]
1/3/5/7/9/11/13/15/17/19/21/23 [RX+]
2/4/6/8/10/12/14/16/18/20/22/24 [RX-]
Cable Cramp
Connection table for sensors: ch13 ~ ch16
CQD-2040
TB402
[CH-13 to 16]
1/6/11/16 [RX+]
2/7/12/17 [RX-]
Cable Cramp
Connection table for sensors: ch17 ~ ch24 (only NDV-1800)
DAU
Term #
CQD-2040
TB404
[CH-17 to 24]
1/3/5/7/9/11/13/15 [RX+]
2/4/6/8/10/12/14/16 [RX-]
Cable Cramp
Connection table for sensors: ch25 ~ ch32 (only NDV-1800)
DAU
Term #
CQD-2040
TB405
[CH-25 to 32]
1/3/5/7/9/11/13/15 [RX+]
2/4/6/8/10/12/14/16 [RX-]
Cable Cramp
Cable Specification
DOC No. 7ZPJD0387C
RCU
Term #
RCU
Term #
NMEA0183
OUT
TX+
TX-
SHIELD
NMEA0183
OUT
TX+
TX-
SHIELD
1-pair x twist pair x 0.75mm
Sensor
Term #
NMEA0183
OUT
TX+
NMEA Output (Positive)
TX-
NMEA Output (Negative)
SHIELD
SHIELD
Sensor
Term #
NMEA0183
OUT
TX+
NMEA Output (Positive)
TX-
NMEA Output (Negative)
SHIELD
SHIELD
Sensor
Term #
NMEA Output (Positive)
NMEA Output (Negative)
SHIELD
Sensor
Term #
NMEA Output (Positive)
NMEA Output (Negative)
SHIELD
2
, shielded
70
Signal Name
Signal Name
Signal Name
Signal Name

Hide quick links:

Advertisement

Table of Contents