6.4. Main Control Board (CDJ-2304) /(RMB: CDK-287) DIP-SW setting
Change a setup of DIP-SW if needed after understanding the purpose of a facility enough.
Initial states are all the switches OFF.
CONF
Function
0 *
EEPROM
1
Radar image error
2
Both radar image error
3
SPARE
4 *
EEPROM
5
CF Card release
6
CF Card format
7 *
Safe mode
CONF DIP-SW
(The * is marked to the switch which can use in the CDK-287..)
Setting
Initialize a configuration data in EEPROM.
OFF: not initialize
ON: Initialize by both of switches 0 and 4 are ON
Alarm as no image signal
OFF: Activate an alarm at receiving no image signal
ON: Inhibit an alarm
Alarm as no image signal from both channel
OFF: Activate an alarm at receiving no image signal
from both channels.
ON: Activate an alarm at receiving no image signal
from any channel.
Initialize a configuration data in EEPROM.
OFF: not initialize
ON: Initialize by both of switches 0 and 4 are ON
Waiting time to release the card
OFF: 5 seconds
ON: 60 seconds
Formatting CF card
OFF: Card is formatted, when abnormalities are
detected on card format at startup.
ON: Card is formatted at startup.
Maintenance mode for MCB
OFF: Normal mode
ON: Safe mode
101
JCY-1800/1850 VDR/S-VDR Installation Guide
Remark
Be sure to return to OFF after
initialization.
Turn ON to inhibit an alarm
by turning off Radar.
Turn ON the switch 1 to
alarm.
Be sure to return to OFF after
initialization.
Choose 60 seconds mode to
record the last 1minutes data.
Don't change
6. Setting