Code 93 Message Length
Scan the bar codes below to change the message length. Refer to
Description
lengths = 0-80. Minimum Default = 0, Maximum Default = 80.
Minimum Message Length
Code 93 Append
This function allows the scanner to append the data from several Code 93 bar
codes together before transmitting them to the host computer. When this function
is enabled, the scanner stores those Code 93 bar codes that start with a space
(excluding the start and stop symbols), and does not immediately transmit the
data. The scanner stores the data in the order in which the bar codes are read,
deleting the first space from each. The scanner transmits the appended data when
it reads a Code 93 bar code that starts with a character other than a space.
Default = Off.

Code 93 Code Page

Code pages define the mapping of character codes to characters. If the data
received does not display with the proper characters, it may be because the bar
code being scanned was created using a code page that is different from the one
the host program is expecting. If this is the case, scan the bar code below, select
the code page with which the bar codes were created (see
188
(page 178) for additional information. Minimum and Maximum
On
Off
Message Length
Maximum Message Length
* Off
ISO 2022/ISO 646