Parameter (Continued)
Current Draw @5VDC
Power Supply Noise Rejection
Illumination LED:
Peak Wavelength
Aiming:
Peak Wavelength Laser
Optical Power Laser
Environmental
Temperature Ranges:
Operating
Storage
Humidity
Mechanical Drop
Vibration
ESD Tolerance
Sealant Rating
Image
Image Size
Scan Performance
Skew Angle
Pitch Angle
Motion Tolerance:
Symbol Contrast
Granit 1981i Industrial Full Range Cordless Scanner
Product Specifications
Parameter
Mechanical
Height
Length
Width
302
Specification
ScanningStandby
470mA, 2.35W100mA, 0.5W
Maximum 100mV peak to peak, 10 to 100 kHz
617nm + 18nm (amber LED)
IEC 62471: "Exempt Risk Group"
650nm
IEC 60825-1: "Class 2"
<1mW
-22F to +122F (-30C to 50C)
-40F to +158F (-40C to 70C)
0 to 95% non-condensing
Operational after 50 drops from 6.5 feet
(1.98m) to concrete at 23°, -30°, and 50°C
Complies with MIL-STD-810G, Method 514.6, Annex
C
Up to 20kV direct air
Up to 8 kV indirect coupling plane
IP65
1280 x 800 pixels
+80° typical, 200 lux, EAN/UPC
+70°typical, 200 lux, EAN/UPC
30 inches per second typical on 13 mil UPC/EAN bar
code 8 in. from scanner nose
1D codes 30% or greater (typical, 200 lux, 13 mil)
2D codes 40% or greater (typical, 200 lux, 20 mil)
Specification
7.7 in. (195.6mm)
5.2 in. (132.1mm)
2.9 in. (73.7mm)