Checking The Configuration - Huawei AR2200-S Series Configuration Manual

Enterprise router
Hide thumbs Also See for AR2200-S Series:
Table of Contents

Advertisement

Huawei AR2200-S Series Enterprise Routers
Configuration Guide - Reliability
The system view is displayed.
Step 2 Run:
bfd cfg-name bind peer-ip ip-address [ vpn-instance vpn-instance-name ] [
interface interface-type interface-number ] source-ip ip-address auto
A static BFD session with automatically negotiated discriminators is set up.
Step 3 Run:
commit
The configuration is committed.
----End

3.4.4 Checking the Configuration

By viewing the type of a BFD session, you can check whether the configurations are successful.
Prerequisite
The configurations of a BFD session with automatically negotiated discriminators are complete.
Procedure
l
----End
Example
# After the configuration is complete, run the display bfd session all verbose command. You
can see that a BFD session of the Static_Auto type has been established. The local and remote
discriminators of this BFD session are 8193 and 8192 respectively and have been obtained based
on automatic negotiation.
<Huawei> display bfd session all verbose
--------------------------------------------------------------------------------
Session MIndex : 67
--------------------------------------------------------------------------------
Local Discriminator
Session Detect Mode
BFD Bind Type
Bind Session Type
Bind Peer IP Address
NextHop Ip Address
Bind Interface
Bind Source IP Address : 195.168.1.1
FSM Board Id
Min Tx Interval (ms)
Issue 01 (2012-01-06)
NOTE
l The source IP address must be specified.
l The peer IP address must be specified, which cannot be a multicast IP address.
NOTE
A BFD session currently does not detect route switching. If the change of bound peer IP address causes a
route to switch to another link, the BFD session is negotiated again only when the original link fails.
Run the display bfd session { all | static | dynamic | discriminator discr-value | peer-ip
peer-ip [ vpn-instance vpn-instance-name ] } verbose command to check information
about a BFD session.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
(One Hop) State : Up
: 8193
Remote Discriminator
: Asynchronous Mode Without Echo Function
: Interface(GigabitEthernet1/0/0)
: Static_Auto
: 195.168.1.2
: 195.168.1.2
: GigabitEthernet1/0/0
: 0
TOS-EXP
: 1000
Min Rx Interval (ms)
3 BFD Configuration
Name : auto
: 8192
: 7
: 1000
151

Advertisement

Table of Contents
loading

Table of Contents