Technical Data Of The 400 V Class - KEB Combivert F5 series Instruction Manual

Power circuit 0.37...37 kw
Hide thumbs Also See for Combivert F5 series:
Table of Contents

Advertisement

Technical data of the 400 V class

2.3
Technical data of the 400 V class
Inverter size
Housing size
Phases
Output rated power
Max. rated motor power
Output rated current
Max. short time current
OC-tripping current
Input rated current
Max. permissible main fuse gG
Rated switching frequency
Max. switching frequency
Power loss at nominal operating
Power loss at DC operating
Standstill current at 4 kHz
Standstill current at 8 kHz
Standstill current at 16 kHz
Min. frequency at continuous full load
Max. heat sink temperature
Motor cable cross-section
Min. braking resistor
Max. braking current
Overload characteristic (see annex)
Input rated voltage
Input voltage range
Input voltage at DC operation
Mains frequency
Output voltage
Output frequency
Max. motor line length shielded at 4 kHz
Max. motor line length shielded at 8 kHz
Max. motor line length shielded at 16 kHz
For use in USA
Max. mains fuse type RK5
MCCB: NKJH Type „E"
1) With the regulated systems F5-M as well as F5-S 5% are to be subtracted as control reserve
2) Max. current before response of the OL-function (F5-M, F5-S, F5-A)
3) Recommended minimum cross section of the motor line for rated power and a cable length of upto 100 m (copper)
4) This data is only valid for units with internal brake transistor GTR 7 (see "unit identification")
5) At rated voltages > 460 V multiply the rated current with factor 0,86
6) At control board BASIC only 2 kHz
7) For UL accepted types see annex
The technical data are for 2/4-pole standard motors. With other pole numbers the inverter must be dimensioned onto the
motor rated current. Contact KEB for special or medium frequency motors.
Site altitude maximal 2000 m. With site altitudes over 1000 m a derating of 1 % per 100 m must be taken into con-
sideration.
GB - 18
05
07
A B A B D A B D
3
3
[kVA]
0.9
1.8
[kW] 0.37
0.75
[A] 1.3
2.6
[A] 2.3
4.7
1)
[A] 2.8
5.6
[A] 1.8
3.6
[A] 16
16
4 16 4
16
[kHz]
[kHz]
4 16 4
16
[W] 45 60 50 90 60 80 105
[W] 44 58 48 87 55 75 100
2)
[A]
1.3
2.6
[A] –
2.6
2)
1.3
2)
[A] –
1.3
2.6
[Hz]
[°C]
1.5
1.5
3)
[mm²]
4)
[Ω] 390
180
120
[A] 2.2 4.5 7.5
4)
[V]
5)
[V]
[V]
[Hz]
[V]
[Hz]
[m] 10
10 30 10
[m] – 8 – 8 20 –
[m] – 4 – 5 10 –
[A] – 5 –
6
7)
[A] – 10 –
10
09
10
B D D B D E D E
3
3
2.8
4.0
1.5
2.2
4.1
5.8
7.4
10.4
8.9
12.5
6
8
16
16
4
8
8
4 16 4
4
16
16
120 140 170 150 185 300 185 250
110 130 160 135 170 285 165 230
4.1
5.8
4.1
5.8 5.2 5.8 –
3.5
4.9 3.5 5.8 – 5.8 9.5 5.8 12 5.7 10 12
6
90 °C (194 °F)
1.5
1.5
110
120
82
7
7.5
10
1
400 (UL: 480)
305...500 ±0
420...720 ±0
50 / 60 ±2
3 x 0...Uin
see control board
100
100
30
50
100
10
10
20
10
12
10
12
12
13
D
3
3
6.6
8,3
4.0
5.5
9.5
12
16.5
17
21.6
29.7
21
25.9
35.6
13
17
20
25
8 16 4 16
2
4
16
16
8
6)
185
160
9.5
12
14.5 16.5
9.5
9.5 12 9.9
2.5
4
82
39 56 39 56
10
21 15 21 15
50
100
100
100
100
100
100
15
25
16
25
14
E
G
3
11
7.5
24.8
29.7
23
25
8 16
16
320 380
295 350
16.5
3
4
39
21
100
100
100
30
30 –

Advertisement

Table of Contents
loading

Table of Contents