Technical data of the 400 V class
2.4

DC supply

The DC input current of the inverter is basically determined by the used motor. The data can be taken from the
motor name plate.
230V class:
I
=
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
DC
400V Class:
I
=
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
DC
The DC input peak current is determined by the operating range.
• if you accelerate on the hardware current limit, the short-time current limit of the inverter must be used in the
formula above (instead of the motor rated current)
• if the motor in normal operation is never stressed with rated torque, it can be calculated with the real motor
current.
GB - 20
√3 • motor rated voltage • motor rated current • motor cos φ
DC voltage (310 V)
√3 • motor rated voltage • motor rated current • motor cos φ
DC voltage (540 V)