Technical Data Of The 230V Class - KEB COMBIVERT F5 Instruction Manual

1.5...4.0kw 230 v 1.5...7.5kw 400 v
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

2.2

Technical data of the 230V class

Inverter size
Housing size
Phases
Output rated power
Max. rated motor power
Output rated current
Max. short time current
OC-tripping current
Input rated current
Max. permissible main fuse gG
Rated switching frequency
Max. switching frequency
Power loss at nominal operating
Power loss at DC supply
Standstill current at 4 kHz
Standstill current at 8 kHz
Standstill current at 16 kHz
Min. frequency at continuous full load
Max. heat sink temperature
Motor cable cross-section
Min. braking resistor
Max. braking current
Overload characteristic
Input rated voltage
Input voltage range Uin
Input voltage at DC operation
Mains frequency
permitted mains forms
Output voltage
Output frequency
Max. motor line length shielded at 4 kHz
Max. motor line length shielded at 8 kHz
Max. motor line length shielded at 16 kHz
1) With regulated systems 5% are to be subtracted as overmodulation capacity
2) Max. current before the OL2 function triggers (not at F5 in operating mode v/f)
3) Recommended minimum cross section of the motor line for rated power and a cable length of upto 100 m
(CU)
4) This data is only valid for units with internal braking transistor (see "unit identification")
5) Protection in accordance with UL see annex B
6) IT system optional
7) Phase conductor grounded mains are only permissible without HF filters
8) The voltage at the motor is dependent on the series-connected units and on the control method (see A.3)
9) The output frequency is to be limited in such way that 1/10 of the switching frequency is not exceeded
The technical data are for 2/4-pole standard motors. With other pole numbers the inverter
must be dimensioned onto the motor rated current. Contact KEB for special or medium fre-
quency motors.
Technical Data of the 230 V Class
[kVA]
[kW]
[A]
[A]
1)
[A]
[A]
[A]
5)
[kHz]
[kHz]
[W]
[W]
[A]
2)
[A]
2)
[A]
2)
[Hz]
[mm²]
3)
[Ω]
4)
[A]
4)
[V]
[V]
[V]
[Hz]
[V]
8)
[Hz]
9)
[m]
[m]
[m]
07
09
D
D
1
3
1
3
1
1.6
2.8
4.0
0.75
1.5
2.2
4
7.0
7.2
12.6
8.6
15.1
21.6
8 5.6 14 9.8 20 14
20 16 20 16 25 20
16
16
16
16
100
130
170
90
120
155
4
7
4
7
4
7
6
6
90 °C (194 °F)
2.5 1.5 2.5 1.5 4 2.5
56
47
7.5
9.5
(see annex A)
230 (UL: 240)
180...260 ±0
250...370 ±0
50 / 60 ±2
TN, TT, IT6), ∆-mains7)
3 x 0...Uin
see control board
100
100
50
100
20
100
10
12
D
D
3
3
6.6
4.0
10
16.5
18
29.7
35.6
23
25
16
8
16
16
210
185
10
16.5
10
16.5
10
10
6
6
4
33
27
12
15