Technical Data; Operating Conditions - KEB Combivert F5 series Instruction Manual

Power circuit 0.37...37 kw
Hide thumbs Also See for Combivert F5 series:
Table of Contents

Advertisement

Technical Data

2.
Technical Data
2.1

Operating conditions

Definition acc.
Site altitude
Ambient conditions during operation
Temperature
Climate
Mechanical
Contamination
Ambient conditions during transport
Temperature
Climate
Mechanical
Contamination
Ambient conditions for the storage
Temperature
Climate
Mechanical
Contamination
Type of protection
Environment
Definition acc.
EMC emitted interference
Cable-based interferences
Radiated interferences
EMC interference immunity
Burst - control lines + bus EN 61000-4-4 2 kV
Burst - mains supply EN 61000-4-4 4 kV
Surge - mains supply EN 61000-4-5 1 / 2 kV
Voltage variation /
voltage drop
Voltage unsymmetries /
Frequency changes
40°C at size 05/230 V with field bus operation
1)
with filter
2)
GB - 14
Standard
EN 61800-2
EN 61800-5-1
EN 60721-3-3
Humidity
Track
Germ. Lloyd
Vibration
EN 60721-3-3 3M1
Gas
Solids
EN 60721-3-2
Humidity
Track
Vibration
Germ. Lloyd
EN 60721-3-2 2M1
Surge EN 60721-3-2 2M1
Gas
Solids
EN 60721-3-1
Humidity
Track
Germ. Lloyd
Vibration
EN 60721-3-1 1M1
Surge EN 60721-3-1 1M1
Gas
Solids
EN 60529
IEC 664-1
EN 61800-3
----
----
ESD EN 61000-4-2 8 kV
EMF EN 61000-4-3 10 V/m
EN 61000-2-1
EN 61000-2-4
Standard/class
Inverter-product standard: rated specifications
Inverter-product standard: general safety
max. 2000 m above sea level
With site altitudes over 1000 m a derating of 1 % per
100 m must be taken into consideration.
extended to -10...45
3K3
With temperature over 45°C to max. 55°C a deration of
5 % per 1 K must be taken into consideration.
3K3
5...85 % (without condensation)
EN50155
max. amplitude of a vibration 1 mm (5...13 Hz)
Part 7-3
max. acceleration amplitude 7 m/s² (13...200 Hz) sine
3C2
3S2
2K3
2K3
(without condensation)
EN50155
max. amplitude of a vibration 3.5 mm (2...9 Hz)
Part 7-3
max. acceleration amplitude 15 m/s² (9...200 Hz) sine
max. 100 m/s²; 11 ms
2C2
2S2
1K4
1K3
(without condensation)
EN50155
max. amplitude of a vibration 1 mm (5...13 Hz)
Part 7-3
max. acceleration amplitude 7 m/s² (13...200 Hz) sine
max. 100 m/s²; 11 ms
1C2
1S2
IP20
Pollution degree 2
Inverter-product standard: EMC
C2
formerly limit A (B optional) according to EN55011
2)
C2
formerly limit A according to EN55011
AD (air discharge) and CD (contact discharge)
Phase-phase / phase-ground
+10 %, -15 %; 90 %
3 %; 2 %
Instructions
°C1)

Advertisement

Table of Contents
loading