Operation of the Unit

4.
Operation of the Unit
4.1

Operation Accessories

4.1.1

With HSP5 cable and without operator

A special cable (part number 00F50C0-0001) is necessary for the control of the KEB
COMBIVERT without operator. It is connected between the HSP5-interface X4A and a
serial RS232-PC-interface (COM1 or COM2). The operation takes place via the PC-program
COMBIVIS.
The HSP5-cable has an integrated level converter. The connection of a serial
standard cable would destroy the PC-interface.
4.1.2

Digital operator (part number 00F5060-1000)

As an accessory for the local operation of the KEB COMBIVERT F5 an operator is available.
To prevent malfunctions, the inverter must be brought into nOP status before connecting /
disconnecting the operator (open control release). When starting the inverter, it is always
started with the last stored values or the factory setting.
Transmit "LED on"
(only 00F5060-2000)
HSP5 diagnostic interface
(only 00F5060-2000)
4.1.3

Interface operator (part number 00F5060-2000)

The interface operator corresponds to the functional range of the digital operator. However,
it is enhanced by a serial RS232/485-interface.
5
4
3
2
1
9
8
7
6
A RS232-cable is needed to connect the interface operator with the PC. The assignment
is represented on the following page.
GB - 18
Interface control
PIN RS485
1
-
2
-
3
-
4
A'
5
B'
6
-
7
C/C'
8
A
9
B
START
ENTER
FUNC.
F/R
SPEED
STOP
X6B
C O M B I V E R T
X6C
X6D
Signal Meaning
-
reserved
TxD
transmission signal RS232
RxD
receive signal RS232
RxD-A receive signal A RS485
RxD-B receive signal B RS485
VP
Voltage supply +5 V (Imax=50 mA)
DGND Data reference potential
TxD-A transmission signal A RS485
TxD-B transmission signal B RS485
5-digit LED Display
Operating-/Error display
Normal "LED on"
Error "LED blinks"
Double function keyboard
RS232/RS485
(only 00F5060-2000)