KEB Combivert F5 series Installation Manual page 38

5.5...7.5kw 230v 4.0...15kw 400v
Hide thumbs Also See for Combivert F5 series:
Table of Contents

Advertisement

CP-Parameter
Value Function
63
Absolut value ANOUT1 > switching level
64
Absolut value ANOUT2 > switching level
65
ANOUT1 > switching level
66
ANOUT2 > switching level
70
Driver voltage activ (safety relay)
73
Absolut active power > switching level
74
Active power > switching level
Unlisted values are only for application mode
Switching level of CP.33 = 100; switching level of CP.34 = 4
1)
CP.35 Limit switch / stopping mode
This parameter determines the reaction of the drive to terminal X2A.14 (F) and/or X2A.15
(R), which are programmed as limit switches. The reaction of the drive is shown in the
table below.
CP.35 Display Response
0
E.PRx Immediate disabling of modulation
1
A.PRx
2
A.PRx Quick stop / holding torque at speed 0
3
A.PRx Immediate disabling of modulation
4
A.PRx
5
A.PRx Quick stop / holding torque at speed 0
None No effect to the drive, fault is ignored !
6
CP.36 External Fault / stopping mode
With the external error monitoring external units can take direct influence on the drive.
This parameter determines the response of the drive to a signal at terminal X2A.12 (I3)
according to following table.
CP.36 Display Response
0
E.PRx Immediate disabling of modulation
1
A.PRx
2
A.PRx Quick stop / holding torque at speed 0
3
A.PRx Immediate disabling of modulation
4
A.PRx
5
A.PRx Quick stop / holding torque at speed 0
None No effect to the drive, fault is ignored !
6
1)
1)
Quick stopping / disabling of modulation after
reaching speed 0
Quick stopping / disabling of modulation after
reaching speed 0
Quick stopping / disabling of modulation after
reaching speed 0
Quick stopping / disabling of modulation after
reaching speed 0
1)
1)
1)
1)
Restart
Remove fault,
reset
Autoreset, if no fault
is present
Inapplicable
Restart
Remove fault,
reset
Autoreset, if no fault
is present
Inapplicable
GB - 37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert f5

Table of Contents