KEB Combivert F5 series Installation Manual page 28

5.5...7.5kw 230v 4.0...15kw 400v
Hide thumbs Also See for Combivert F5 series:
Table of Contents

Advertisement

CP-Parameter
dulation is switched off!
CP.29 Analog output 1 / Function
CP.29 defines the function of analog output 1.
Value Function
0
Absolute actual frequency CP.3
1
absolute set frequency CP.2
2
actual frequency CP.3
3
set frequency CP. 2
4
output voltage CP.9
5
DC link voltage CP.7
6
apparent current CP.4
7
active current ru.17
8...10 only application mode
11
absolute active current ru.17
12
power stage temperature ru.38
13
motor temperature ru.46
14...18 only application mode
19
ramp output frequency ru.2
20
absolute ramp output frequency ru.2
CP.31 Relay output 1 / function (terminals X2A.24...26)
CP.32 Relay output 2 / function (terminals X2A.27...29)
The switching level of CP.31 is pre-set to 100,00.
The switching level of CP.32 is adjusted by CP.33!
Va-
Function
lue
0
No function (generally off)
1
Generally on
2
Run signal; also by DC-braking
3
Ready signal (no error)
4
Fault relay
5
Fault relay (without auto-reset)
6
Warning or error message at abnormal stopping
7
Overload pre-warning
8
Overtemperature alert signal power stage
9
External Overtemperature alert signal motor
11
Overtemperature alert signal interior OHI
12
Cable breakage 4...20 mA on analog input 1
14
max. constant current (Stall, CP.25) exceeded
15
max. ramp current (LA-Stop, CP.24) exceeded
16
DC-braking active
20
Actual value = set value (CP.3 = Fcon; rcon; not at noP, LS, error, SSF)
21
Accelerate (CP.3=FAcc, rAcc, LAS)
22
Decelerate (CP.3 = FdEc, rdEc, LdS)
23
Real direction of rotation = set direction of rotation
24
Utilization (CP.6) > switching level
GB - 24
Scaling factor
0...100 % (0...±100 %)
0...100 Hz
0...100 Hz
0...±100 Hz
0...±100 Hz
0...500 V
0...1000 V
0...2 • rated current
0...2 • ±rated current
0...2 • rated current
0...100 °C
0...100 °C
0...±100 Hz
0...100 Hz