APPENDIX 5 ALERT LIST
ALF
ALR
No.
Inst.*
No.
30300
16
099
30331
-
331
30380
131
380
30400
1
255
30400
2
256
AP-52
Priority/
Alert name
Category
Sensor Adapter 16
Caution/B
COM Timeout
Selected Gyro sta-
Warning/
tus missing
B
AIS COM Error
Warning/
B
Gyro 1 COM Error
Caution/B
Gyro 2 COM Error
Meaning
Communication er-
Check the connec-
ror with No.16 sen-
tion with No.16
sor adapter is
sensor adapter
detected. 30 sec-
and network.
onds timeout.
No.16 sensor
adapter is turned
off, or there is a
problem with net-
work.
When connected
If the error fre-
with Double Gyro
quently occurs,
System, instrument
contact FURUNO
produced by Yok-
and inform fre-
ogawa Electric,
quency of occur-
"Double Gyro" sta-
rence.
tus cannot be ac-
quired.
Data from AIS has
Check the connec-
been discontinued
tion with AIS and
for more than set
network.
time.
(Set at installation)
Default: 60 seconds
AIS is turned off, or
there is a problem
with network.
Data from No.1 gyro
Check the connec-
has been discontin-
tion with No.1 gyro
ued for more than
and network.
set time.
(Set at installation)
Default: 60 seconds
No.1 gyro is turned
off, or there is a
problem with net-
work.
Data from No.2 gyro
Check the connec-
has been discontin-
tion with No.2 gyro
ued for more than
and network.
set time.
(Set at installation)
Default: 60 seconds
No.2 gyro is turned
off, or there is a
problem with net-
work.