25.4
Alert Category and Alert Acknowledgement
From Connected Equipment, AMS
Category A alert
Acknowledged from the equipment that generated the alert: The alert is acknowl-
edged at both the equipment and the AMS and their buzzers stop.
Category B alert
Acknowledged from the equipment that generated the alert: The alert is acknowl-
edged at the equipment and the buzzer is temporarily silenced.
Category C alert
Acknowledged from the equipment that generated the alert: The alert is acknowl-
edged at the equipment that generated the alert.
25.5

How to Acknowledge an Alert From the AMS

There are two methods to acknowledge an alert from the AMS:
• Trackball: Click the alert name on any window in the AMS.
• ALARM ACK key: Push the key on the connected Control Unit.