How To Adjust The Function Pump Pressure Compensator - Genie GTH-1056 Service And Repair Manual

From gth1016e-11305 to gth1016e-11799 includes gth1016e-11281 gth1016e-11282 gth1016e-11286 from gth10e-11800
Hide thumbs Also See for GTH-1056:
Table of Contents

Advertisement

Service and Repair Manual
Hydraulic Pump
4
Loosen the set screw for the standby pressure
adjustment screw.
1 standby pressure adjustment screw
2 set screw
3 hydraulic supply line (from tank)
5
Adjust the function pump standby pressure.
Turn the adjustment screw clockwise to
increase the pressure or counterclockwise to
decrease the pressure. Tighten the set screw.
6
Turn the engine off and remove the pressure
gauge.
Bodily injury hazard. Spraying
hydraulic oil can penetrate and
burn skin. Loosen hydraulic
connections very slowly to allow
the oil pressure to dissipate
gradually. Do not allow oil to
squirt or spray.
52
How to Adj ust the Functi on Pump Press ure Compens ator
How to Adjust the Function Pump
Standby Pressure
Note: Two people will be required to perform this
procedure.
1
Connect a 0 to 5000 psi / 0 to 350 bar
pressure gauge to test port 'TP' on the primary
function manifold. Refer to Primary Function
Manifold Components.
2
Start the engine and allow the engine to run at
low idle.
3
Fully retract the boom.
4
Continue to activate the boom retract function
and observe the pressure reading on the
pressure gauge.
Result: The pressure gauge reads
3190±50 psi / 220±3.4 bar. The pump is
functioning correctly. Proceed to step 7.
Result: The pressure gauge fails to read
3190±50 psi / 220±3.4 bar. The pressure
setting needs to be adjusted. Proceed to step
5.
GTH-1056
April 2017
Part No. 1278145

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents