Genie GTH-1056 Service And Repair Manual page 97

From gth1016e-11305 to gth1016e-11799 includes gth1016e-11281 gth1016e-11282 gth1016e-11286 from gth10e-11800
Hide thumbs Also See for GTH-1056:
Table of Contents

Advertisement

April 2017
SPN = Suspect Parameter Number
ASPN = Alternate Suspect Parameter Number
FMI = Failure Mode Identifier
SPN
ASPN FMI
Description
2791
0
EGR actuator, temperature critical high
2
EGR actuator, CAN error
3
EGR actuator supply voltage is above the maximum threshold
4
EGR actuator supply voltage is below minimum threshold
6
EGR actuator current is above maximum threshold
7
EGR actuator, actuator blocked or broken spring detected
12
EGR actuator, internal electrical fault
13
EGR actuator, EOL calibration error or learning process aborted or learning process out of
range
16
EGR actuator, temperature high
2797
4
Injector diagnostics; timeout error of short circuit to ground measurement cyl. Bank 0
2798
4
Injector diagnostics; short circuit Bank 0, Bank 1
Injector diagnostics; timeout error of short circuit to ground measurement cyl. Bank 1
3031
0
AdBlue-Tank temperature: maximum exceeded
1
DEF-Tank temperature: below minimum
3
Sensor error urea tank temperature; short circuit to battery
4
Sensor error urea tank temperature; short circuit to ground
3224
1
Nox sensor upstream of SCR Catalysator; low signal not plausible
2
NOx Sensor; CAN DLC error
9
NOx Sensor; CAN Timeout
3234
2
NOx Sensor; CAN DLC error
9
NOx Sensor; CAN Timeout
11
Nox Sensor downstream of SCR Catalysator; plausibility error "stuk in range"
3241
0
Sensor SCR catalyst upstream temperature too high; plausibility error
1
Sensor SCR catalyst upstream temperature too low; plausibility error
Part No. 1278145
Deutz TCD3.6 Engine Fault Codes
GTH-1056
Service and Repair Manual
87

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents