SPN = Suspect Parameter Number
ASPN = Alternate Suspect Parameter Number
FMI = Failure Mode Identifier
SPN
ASPN FMI
Description
23698 64946 11
Shut off request from supervisory monitoring function
23704
12
Timeout Error of CAN-Transmit_Frame EEC3
23717 64965 12
Timeout Error of CAN-Transmit-Frame AmbCon; Weather environments
23718 64966 3
SCR main relay (primary side); short circuit to battery
4
SCR main relay (primary side); short circuit to ground
5
SCR main relay (primary side); open load
12
SCR mainrelay; powerstage over temperature (only CV56B)
SCR mainrelay; short circuit to battery (only CV56B)
SCR mainrelay; short circuit to ground (only CV56B)
SCR mainrelay; open load (only CV56B)
23719 64967 3
SCR heater urea supplymodule; short circuit to battery
4
SCR heater urea supplymodule; short circuit to ground
5
SCR heater relay urea supply module; open load
23720 64968 2
Urea supply module heater temperature; plausibility error
8
Urea supply module heater temperature; signal disrupted
23721 64969 2
Urea supply module heater temperature; plausibility error
8
Urea supply module temperature; signal disrupted
11
Urea supply module temperature measurement not available
23722 64970 8
Urea supply module PWM signal; signal disrupted