Service and Repair Manual
Deutz TCD3.6 Engine Fault Codes
SPN = Suspect Parameter Number
ASPN = Alternate Suspect Parameter Number
FMI = Failure Mode Identifier
SPN
ASPN FMI
Description
3248
0
Exhaust gas temperature particulate filter downstream; out of range, system reaction initiated
1
Exhaust gas temperature particulate filter downstream; out of range, system reaction initiated
2
Sensor exhaust gas temperature downstream DPF; plausibility error
4
Sensor error particle filter downstream temperature; signal range check low
3251
0
Physical range check high for differential pressure (DPF); shut off regeneration
1
Physical range check low for differential pressure (DPF); shut off regeneration
3253
2
Sensor differential pressure (DPF); plausibility error
3
Sensor error differential pressure (DPF); signal range check high
4
Sensor error differential pressure (DPF); signal range check low
3361
3
Urea dosing valve; short circuit to battery
4
Urea dosing valve; short circuit to ground
7
AdBlue dosing valve blocked (SCR)
3519
3
DEF quality sensor, internal temperature sensor short circuit to battery or open lead
4
DEF quality sensor, internal temperature sensor short circuit to ground
12
DEF tank temperature, temperature too high
13
Temperature at UQS invalid
3520
3
DEF quality sensor, short circuit to battery or open load
4
DEF quality sensor, short ciruit to ground
13
Urea quality at UQS invalid
3532
3
DEF level at UQS out of max. physical range
3
Sensor error urea tank level; signal range check high
4
Quality at UQS of of min. physical range
4
Sensor error urea tank level; signal range check low
3699
2
DPF differential pressure sensor and a further sensor or actuator CRT system defective
14
Maximum stand-still-duration reached; oil exchange required
Temperature sensor us. and ds. DOC simultaneously defect
3711
12
Regeneration temperature (PFltRgn LigtOff) not reached; regeneration aborted
3936
14
Standstill request ignored too long